Quantity
Distance
Dotting Time
Dotting Times
Reset
Set as Default Pen Number
OK
Close
:
Basic Parameter Area:
Current Pen Number: The set of marking parameters currently used. In
SeaCAD, the concept of “pen” is equivalent to a set of given marking
parameters.
Marking Quantity processing (pieces): The marking times for each object
during one marking are equivalent to the marking quantity in its marking
parameters.
Speed: The marking speed of current marking parameters.
Power: This item indicates the power percentage of the current marking
parameter, and 100% refers to the maximum power of current laser.
Frequency: The laser’s frequency in the current marking parameter.
Duty Ratio Mopa pulse width: The ratio of laser pulse duration to pulse
period.
Start TC: Delay time for laser ON at the beginning of marking. The proper
Start TC parameters set can eliminate the “match head” appears at the
beginning of marking, while the too large ones may cause miss at the initial
segment. This value may be negative, which indicates that the laser emits
light in advance.
Opening delay: Delay time of laser on at the beginning of marking. Setting
163 / 217