Other Features

Other features are provided for the USB3 Vision cameras on the device list, including U3V Transfer settings, device user ID settings, GenICam XML settings, etc.

U3V Transfer Settings

You can edit the packet size and streaming channels for a USB3 Vision camera.

Right-click a USB3 Vision camera and then click U3V Transfer Setting to open the U3V Transfer setting window, and then configure Packet Size (value range: 64 to 20,480 KB, default value: 1024 KB) and Streaming Channel(s) (value range: 1 to 10, default value: 8) according to the performance of the USB frame grabber. The lower the performance of the USB frame grabber, the smaller the Packet Size and the more Streaming Channel(s) you should set so as to alleviate data transmission between and camera and the Software.
Note:

U3V transfer settings is only available when the camera is connected or in acquisition.

Save GemICam XML

Right-click a USB3 Vision camera, and then click Save GemICam XML to save the camera information as XML file for secondary development of the Software.

Note:

Saving GemICame XML is only available when the camera is connected or in acquisition.

Rename User ID

Right-click a USB3 Vision camera, and then click Rename User ID to edit user ID of the camera.

Note:

Renaming user ID is only available when the camera is connected or in acquisition.

Stick Camera to Top

Right-click a USB3 Vision camera and then click Stick to Top to stick the camera to the top of the USB3 Vision camera list.