GigE Area Scan Camera User Manual
Figure 12-29 Set Sequencer Control
2. Set Sequencer Set Total Number to configure how many groups to join sequencer
according to actual demands.
Note
Up to 8 groups of parameters can be configured.
3. Set Sequencer Set Selector to select one group of parameters, and set Sequencer
Feature Selector to configure specific parameters.
Figure 12-30 Sequencer Feature Selector
Note
You should go to the corresponding parameters to set their detailed parameters.
Sequencer Feature Enable is enabled by default for configured parameters.
4. (Optional) Click Execute in Sequencer Set Load to load selected parameters in
Sequencer Set Selector.
5. (Optional) Click Execute in Sequencer Set Save to save the selected group of
parameters.
6. Repeat step 3 to step 5 to configure other group of parameters.
7. Select On as Sequencer Mode to start sequencer after configuration.
Note
You cannot configure detailed parameters of group of parameters once sequencer is
started.
69