GigE Area Scan Camera User Manual
PNP Device
It is recommended to use 330 Ω pull-down resistor.
PWR
VCC
Camera Power
Bi-direction I/O
Camera Power Ground
PNP Power
●
Signal Line
● ● PNP Power Ground
GND of PWR and VCC
PNP Device
Figure 11-13 Input Signal Connects to PNP Device
NPN Device
● If the VCC of NPN device is 24 VDC, it is recommended to use 4.7 KΩ pull-up resistor.
● If the VCC of NPN device is 12 VDC, it is recommended to use 1 KΩ pull-up resistor.
PWR
VCC
Camera Power
Bi-direction I/O
●
NPN Power
● Signal Line
Camera Power Ground
●
NPN Power Ground
GND of PWR and VCC
NPN Device
Figure 11-14 Input Signal Connects to NPN Device
53