GigE Area Scan Camera User Manual
Chapter 11 I/O Electrical Features and Wiring
11.1 I/O Electrical Features
11.1.1 Electrical Features of Input Signal
The internal circuit of opto-isolated input (Line 0) is as follows.
Note
● The maximum input current of Line 0 is 25 mA.
● Make sure that the input voltage is not from 1 VDC to 3.3 VDC as the electric status
between these two values are not stable.
● The breakdown voltage is 30 VDC. Keep voltage stable.
VCC
GPI
Line 0+
Line 0-
Figure 11-1 Internal Circuit of Input Signal
Logic 1
Input Level
Logic 0
Input Level
Internal Logic
TDR
TDF
Figure 11-2 Input Logic Level
45