GigE Area Scan Camera User Manual
Trigger_in 1
Strobe
Trigger_in 2
Trigger
delay
Strobe
delay Duration
Trigger_in 3
Trigger
delay
Trigger
delay
Sensor
Exposure
Exposure 1
Exposure 2
Exposure 3
Figure 10-9 Sequence Diagram of Strobe Line Delay
Set Strobe Line Pre Delay
The device also supports the function of strobe line pre delay, which means that the strobe
signal takes effect early than exposure. This function is applied to the external devices
that have slow response speed.
Click Digital IO Control → Strobe Line Pre Delay, and enter Strobe Line Pre Delay
according to actual demands.
Figure 10-10 Set Strobe Pre Line Delay
The sequence diagram of strobe line pre delay is shown below.
Trigger_in 1
Strobe
Trigger_in 2
Trigger
delay
Duration
Trigger_in 3
Trigger
delay
Trigger
delay
Sensor
Exposure
Exposure 1
Strobe pre delay
Exposure 2
Exposure 3
Figure 10-11 Sequence Diagram of Strobe Pre Line Delay
44