GigE Area Scan Camera User Manual
10.2.2 Enable Strobe Signal
The strobe signal is used to directly output I/O signal to external devices when the device’s
event source occurs.
Steps
1. Go to Digital IO Control Line Source, and select Line Source according to actual
demands.
2. Enable Strobe Enable.
Figure 10-3 Enable Strobe Signal
The supported line sources are as follows:
Table 10-1 Line Source Description
Line Source
Description
Exposure Start Active
The device outputs signals to external devices when it starts
exposure.
Exposure End Active
The device outputs signals to external devices when it stops
exposure.
Acquisition Start Active The device outputs signals to external devices when it starts
acquiring images.
Acquisition Stop Active
The device outputs signals to external devices when it stops
acquiring images.
Frame Burst Start Active The device outputs signals to external devices when the
device’s frame burst starts.
Frame Burst End Active The device outputs signals to external devices when the
device’s frame burst stops.
Frame Trigger Wait
The device is currently waiting for a frame start trigger.
41