GigE Area Scan Camera User Manual
If the 1st frame image’s exposure time of the 2nd trigger signal is not earlier than the
device’s last frame creation time of the 1st trigger signal, and then the 2nd trigger signal’s
1st frame image is created normally.
Trigger_in1
Trigger_in2
Trigger_in3
Sensor
Exposure
Exposure1
Exposure2
Exposure3
Frame1
Readout
Frame2
Readout
Figure 9-23 Second Frame Created Normally
If the 1st frame image’s exposure time of the 2nd trigger signal is earlier than the device’s
last frame creation time of the 1st trigger signal, and then the device will delay this
exposure time. Thus making sure this exposure time is not earlier than the device’s last
frame creation time of the 1st trigger signal.
Trigger_in1 Trigger_in2
Sensor
Exposure
Exposure1
Frame1
Readout
Exposure Time
Exposure2
Frame2
Readout
Figure 9-24 Sequence Diagram
Note
The three sequence diagrams above use rising edge as trigger activation.
9.7.5 Set Trigger Debouncer
The trigger debouncer function allows the device to filter out unwanted short external
trigger signal that is input to the device.
Go to Digital IO Control Line Debouncer Time, and enter Line Debouncer Time
according to actual demands. The range of Line Debouncer Time is from 0 μs to 1000000
μs.
Note
If the Line Debouncer Time you set is greater than the time of trigger signal, this trigger
signal will be ignored.
38