9.7.2 Set Trigger Activation
The device supports triggering image acquisition in the rising edge, falling edge, level high,
level low or any edge of the external signal. Go to Acquisition Control Trigger
Activation, and select Rising Edge, Falling Edge, Level High or Level Low as Trigger
Activation.
Rising Edge: It means that when the level signal sent by external device is in rising edge,
the device receives trigger signal and starts to acquire images.
Falling Edge: It means that when the level signal sent by external device is in falling edge,
the device receives trigger signal and starts to acquire images.
Level High: The level high of the trigger signal is valid. As long as the trigger signal is in
level high, the device is in image acquisition status.
Level Low: The level low of the trigger signal is valid. As long as the trigger signal is in
level low, the device is in image acquisition status.
Figure 9-18 Set Trigger Activation
9.7.3 Set Trigger Delay
The trigger delay function allows the device to add a delay between the receipt of trigger
signal and the moment the trigger becomes active. Go to Acquisition Control Trigger
Delay, and enter Trigger Delay, and the unit is μs.
Figure 9-19 Set Trigger Delay