GigE Area Scan Camera User Manual
Figure 9-12 Set and Execute Counter Trigger
When using counter trigger, you need to set parameters of Counter and Timer Control as
shown below.
Table 9-2 Parameters of Counter and Timer Control
Parameter
Read/Write
Description
Counter Selector
Read & Write
It selects counter source. Counter 0 is
available only at present.
Counter Event Source Read & Write
It selects the signal source of counter trigger.
Line 0 or Line 2 is available. This parameter is
disabled by default.
Counter Reset Source Read & Write
It selects the signal source of resetting
counter. Software is available only. This
parameter is disabled by default.
Counter Reset
Write is available It resets counter and it can be executed only
under certain when selecting Software as Counter Reset
condition
Source.
Counter Value
Read & Write
It is the counter value with the range of 1 to
1023.
Counter Current Value Read Only
It displays the number of executed external
trigger.
Figure 9-13 Counter and Timer Control