GigE Area Scan Camera User Manual
9.6.2 Set and Execute Hardware Trigger
The device has one opto-isolated input (Line 0), and one bi-directional I/O (Line 2) that can
be configured as input signal. The steps for configuring Line 2 as input signal as follows.
Steps
1. Go to Digital IO Control and select Line 2 as Line Selector.
2. Select Input as Line Mode.
Figure 9-10 Set Line 2 as Input Signal
In hardware trigger, external device sends trigger signal to the device to acquire images via
I/O connector.
Steps
1. Go to Acquisition Control → Trigger Mode, and select On as Trigger Mode.
2. Select Line 0 or Line 2 as Trigger Source according to actual demands.
Figure 9-11 Set and Execute Hardware Trigger
9.6.3 Set and Execute Counter Trigger
In counter trigger, the counter sends trigger signal to the device to acquire images.
Steps
1. Go to Acquisition Control → Trigger Mode, and select On as Trigger Mode.
2. Select Counter 0 as Trigger Source.
32