GigE Area Scan Camera User Manual
13.3 Set Action Command
Note
● The action command function may differ by device models.
● Only V3.1.0 and above version of MVS client software support GigE Vision action
command.
The action command allows you to execute actions on multiple devices at roughly the
same time by using a single broadcast protocol message.
Steps
1. Go to Transport Layer Control → GEV IEEE 1588, and enable GEV IEEE 1588.
2. Go to Acquisition Control → Trigger Selector, and select Frame Burst Start.
3. Select On as Trigger Mode.
4. Select Action 1 as Trigger Source.
5. Go to Tool → GigE Vision Action Command in the menu bar.
Figure 13-7 GigE Vision Action Command
6. Select Network Interfaces to set the subnet that the command to be sent to.
7. Enter Device Key, Group Key, and Group Mask.
Table 13-3 Parameter Description
MVS Parameter
Name
Device Parameter Name
Description
Device Key
Action Control → Action Device Key
The parameter value
should be the same.
94