N:1001;S:The zero speed of the spindle; N:1002;S:The first speed of the spindle; N:1003;S:The second speed of the spindle; N:1004;S:The third speed of the spindle; N:1005;S:The fourth speed of the spindle; N:1006;S:The fifth speed of the spindle; N:1007;S:The sixth speed of the spindle; N:1008;S:The seventh speed of the spindle; N:1009;S:The spindle was successfully turned ON; N:1010;S:The spindle was successfully turned OFF; N:1011;S:The vibrating knife is turned ON; N:1012;S:The vibrating knife is turned OFF; N:1013;S:The vacuum pump is turned ON; N:1014;S:The vacuum pump is turned OFF; N:1015;S:The tool is completed; N:1016;S:Release tool is completed; N:1017;S:The vacuum cleaner is turned ON; N:1018;S:The vacuum cleaner is turned OFF; N:1019;S:Move to the target position; N:1020;S:Moving was completed; N:1021;S:X axis is in place; N:1022;S:Y axis is in place; N:1023;S:Z axis is in place; N:1024;S:A axis is in place; N:1025;S:B axis is in place; N:1026;S:C axis is in place; N:1027;S:XY axis is in place; N:1028;S:Start to return the tool; N:1029;S:The tool is completed; N:1030;S:Start taking the tool; N:1031;S:The tool is completed; N:1032;S:Start to change the tool; N:1033;S:The tool fails, the tool setting signal is not triggered; N:1034;S:The cross test is completed; N:1035;S:No mark point graphic is recognized; N:1036;S:First point sampling; N:1037;S:Second point sampling; N:1038;S:Third point sampling; N:1039;S:Fourth point sampling; N:1040;S:CCD sampling is completed; N:1041;S:Correction is completed; N:1042;S:Initialization starts; N:1043;S:The network connection failed, and the initialization is completed; N:1044;S:Initialization is completed; N:1045;S:The connection is successful; N:1046;S:Return to the workpiece origin; N:1047;S:Processing begins; N:1048;S:Processing is completed; N:1049;S:X-axis coarse positioning stage; N:1050;S:X-axis back to 0 coarse positioning failed, the limit signal is not triggered; N:1051;S:X-axis coarse positioning retreat stage; N:1052;S:X-axis back to 0 coarse positioning back-fail, the signal is abnormal; N:1053;S:X-axis fine positioning stage; N:1054;S:X-axis back 0 fine positioning failed, the limit signal is not triggered; N:1055;S:X-axis fine positioning retreat stage; N:1056;S:X-axis back 0 fine positioning retraction failed, the signal is abnormal; N:1057;S:X axis zero return success; N:1058;S:Y-axis coarse positioning stage; N:1059;S:Y axis returns 0 coarse positioning failure, the limit signal is not triggered; N:1060;S:Y-axis coarse positioning retreat stage; N:1061;S:Y-axis back 0 coarse positioning back-fail, the signal is abnormal; N:1062;S:Y-axis fine positioning stage; N:1063;S:Y-axis back 0 fine positioning failed, the limit signal is not triggered; N:1064;S:Y-axis fine positioning retreat stage; N:1065;S:Y-axis back 0 fine positioning retraction failed, the signal is abnormal; N:1066;S:Y axis zero return success; N:1067;S:Z-axis coarse positioning stage; N:1068;S:Z axis returns 0 coarse positioning failure, the limit signal is not triggered; N:1069;S:Z-axis coarse positioning retreat stage; N:1070;S:Z-axis back to 0 coarse positioning back-fail, the signal is abnormal; N:1071;S:Z-axis fine positioning stage; N:1072;S:Z-axis back 0 fine positioning failed, the limit signal is not triggered; N:1073;S:Z-axis fine positioning retreat stage; N:1074;S:Z-axis back 0 fine positioning retraction failure, signal abnormality; N:1075;S:Z axis zero return success; N:1076;S:All zero return is completed; N:1077;S:C-axis coarse positioning stage; N:1078;S:C axis returns 0 coarse positioning failure, the limit signal is not triggered; N:1079;S:C-axis coarse positioning retreat stage; N:1080;S:C-axis back to 0 coarse positioning back-fail, the signal is abnormal; N:1081;S:C-axis fine positioning stage; N:1082;S:C-axis back 0 fine positioning failed, the limit signal is not triggered; N:1083;S:C-axis fine positioning retreat stage; N:1084;S:C-axis back 0 fine positioning retraction failed, the signal is abnormal; N:1085;S:C axis zero return success; N:1086;S:Spindle without a clamped tool; N:1087;S:Abnormal spindle stop signal; N:1088;S:Count tool signals abnormal 1; N:1089;S:Count tool signals abnormal 2; N:1090;S:The tool clamping signal is abnormal, and the loose tool fails; N:1091;S:Tool Magazine failed to launch; N:1092;S:Tool Magazine return failed; N:1093;S:The program is abnormal and the X-axis movement is not in place; N:1094;S:Program is abnormal, X axis movement is not in place, encoder feedback error; N:1095;S:The program is abnormal and the Y-axis movement is not in place; N:1096;S:Program is abnormal, Y axis movement is not in place, encoder feedback error; N:1097;S:The program is abnormal and the Z-axis movement is not in place; N:1098;S:Program is abnormal, Y axis movement is not in place, encoder feedback error; N:1099;S:Wait for 0 speed signal ; N:1100;S:Read IO; N:1101:IO offset; N:1102:Tool magazine rollback; N:1103:Waiting for the tool magazine back signal; N:1104:Start to return; N:1105:Incorrect cutter number; N:1106:Abnormal cutter position, abnormal tool count signal; N:1107:The current tool number T0, the tool clamping signal is abnormal, and the tool change stops; N:1108:Abnormal spindle speed signal; N:1109:Stop; N:1110:Stop triggering; N:1111:Start tool setting; N:1112;S:Fine positioning stage; N:1113;S:The tool setting signal is abnormal; N:1114;S:The setting of the starting point of the tool setting is abnormal; N:1115;S:The current tool number is 0, no tool setting operation is allowed; N:1116;S:Recognition abnormality, did not move to the center of the marked point!; N:1117;S:Open vacuum break; N:1118;S:Close vacuum break; N:1119;S:Release tool signal is abnormal, release tool fails;