20006:Analog minimum voltage value; unit V. When using analog
mode, changing this parameter modifies the board output analog to get
the minimum value.
20007:Analog maximum voltage value; unit V. When using analog
mode, changing this parameter modifies the board output analog to get
the maximum value.
20008:Spindle speed control mode; change this parameter to
select the spindle control mode. 1. Analog quantity; 2. Multi-speed.
20010:The 0th step speed; the multi-speed speed 0th step speed
should be the same as the 0th step speed setting of the inverter.
20011:The 1st step speed; the multi-speed speed 1st speed should
be the same as the 1st speed setting of the inverter.
20012:The 2nd step speed; the multi-speed second step speed
should be the same as the second step speed setting of the inverter.
20013:The 3rd step speed; the multi-speed third step speed
should be the same as the third step speed setting of the inverter.
20014:The 4th step speed; the fourth speed of the multi-speed,
should be the same as the fourth step of the inverter.
20015:The 5th step speed; the multi-speed 5th step speed should
be the same as the 5th step speed setting of the inverter.
20016:The 6th step speed; the 6th step speed of the multi-speed,
should be the same as the 6th speed setting of the inverter.
20017:The 7th step speed; the 7th step speed of the multi-speed,
should be the same as the 7th speed setting of the inverter.