change is completed, the axis signal wiring on the board also needs
to be modified to make the system operate normally. The Y axis and Z
axis settings are the same.
11002Whether it must return to zero before processing; 1 is
yes, 0 is no. The system defaults to zero to ensure normal use, and
the user can modify the tool's own requirements.
11003Motor type; 1 is stepping and 2 is servo. Set according to
the motor used by the machine.
11005Whether the connection is automatically zeroed; whether
the automatic zero return option is prompted after the computer and
the control board are successfully connected. 1 is yes, 0 is no.
11101X-axis origin; the mechanical coordinate of the trigger
point of the X-axis mechanical zero return limit signal, in mm. This
parameter is set according to the machine limit switch position and
is provided by the manufacturer. The settings for the Y axis and the
Z axis are the same.
11201Initial orientation of the X axis; 1 positive, -1
negative. Set according to the position of the machine limit switch.
If it is installed on the stroke minimum side, select the negative
direction; if it is installed on the stroke maximum side, select the
forward direction. The Y axis and Z axis settings are the same.
11301X coarse positioning speed; unit mm / min. In the process
of zero return, the machine first triggers the limit signal at a
faster speed, which is the coarse positioning speed. The speed is not
too fast, and the speed is too fast, which will cause the machine to
pass through during the zero return process. The settings for the Y
axis and the Z axis are the same.