成都兴多维科技有限公司
Chengdu multidimensional robotization technology company
save the new template. Now you can select and use the template in the
[Template List].
The camera can be set in the [Camera Settings] column below. The
page has 4 rotation angles for the user to select. When using it for
the first time, the screen is rotated according to the requirements.
When the screen is normal, the software will save the setting when
exiting, and do not need to modify it multiple times. .
When the actual motion direction of the motion does not match the
direction of motion of the image display, check [Flip Horizontal]
below, the view will be flipped horizontally; check [Vertical Flip]
to try to flip vertically.
Slide the [Gray Value] slider to adjust the brightness of the
image. The camera itself can adjust the brightness. This option is
not recommended for modification. Sliding [Proximity] slider will
adjust the accuracy of identifying Mark points. The larger the value,
the larger the recognition probability but the more likely to be
misidentified. The smaller the value, the lower the probability of
misrecognition and the more accurate the recognition.
6.3.Camera switch and processing
At the bottom of the camera page, you can control the CCD.
Click [CCD] to process and the software will recognize it and
then process it. Make sure the camera recognizes the first Mark
point before processing. Click [CCD] to simulate the wake-up
simulation and view the simulation results. [Turn on the camera]
to turn the camera on; [Turn off the camera] to turn the camera
off.