Chapter 11 Parameter Management
Effective level of
origin
Effective level of
positive limit
Effective level of
negative limit
Effective level of
emergency stop
Positive limiting effective for
X/Y/Z axes or not
Negative limiting effective for
X/Y/Z axes or not
0: Low level effective
1: High level effective
0: Low level effective
1: High level effective
0: Low level effective
1: High level effective
0: Low level effective
1: High level effective
Restart
Restart
Restart
Restart
11.5.2 Machining Parameter
Parameter
Meaning and Function
Value Range
Effective
Time
Idling Speed
Speed of cutter when idling
[Take-off speed to max.
Immediately
speed of each axis]
Safety height
System consider horizontal
motion at this height safe
[5,500]
Immediately
Default feeding
speed
Default feeding speed of
system
[Take-off speed to max.
Immediately
speed of each axis]
Adopt default
feeding speed
Speed specified in the file
ineffective when adopting
default feeding speed
1 Adopt default feeding
speed
Immediately
0 Adopt specified speed
in the file
Diameter of rotary
workpiece
Diameter of machining
workpiece
[0-99999]
Immediately
Cutter lifting
Height of cutter lifting upward
capacity of Z axis along Z direction when cutter
[1,1000]
Immediately
when pausing
pausing
Cutter change Whether system prompts cutter
notification effective change when there are cutter
0 (No): Ineffective
1 (Yes): Effective
Immediately
40
    "