ACD320 user manual
Parameter Description
the detecting time exceeds the feedback disconnected detecting time, the system will send an
alert of feedback disconnecting failure . (U-25)
Function Code
Name
Setting Range
Default
Value
F4.29
Multi-Speed 0
-100.0~100.0%
0.0%
F4.30
Multi-Speed 1
-100.0~100.0%
0.0%
F4.31
Multi-Speed 2
-100.0~100.0%
0.0%
F4.32
Multi-Speed 3
-100.0~100.0%
0.0%
F4.33
Multi-Speed 4
-100.0~100.0%
0.0%
F4.34
Multi-Speed 5
-100.0~100.0%
0.0%
F4.35
Multi-Speed 5
-100.0~100.0%
0.0%
F4.36
Multi-Speed 7
-100.0~100.0%
0.0%
Note: The multi-speed symbol defines the operation direction. If it is negative, the operation
direction is reverse. Frequency setting 100.0% is corresponding to maximum frequency(F0.04).
When MI1=MI2=MI3=OFF,the input mode is chosen by F0.03. When terminals MI1、
MI2、MI3 are not all OFF and multi-step speed run, priority of multi-step speed is higher than the
input of keyboard,simulation and communication frequency, through the combined code, 8-step
speed can be chosen at most.
Fig.6-20multi-speed logic Diagram
The selection of stop channel starting is also determined by function code F0.01 when
inverter is running at multi- speed, and the multi- speed control process is shown in Fig.6-20.
The relation between MI1、MI2、MI3 terminal and multi-speed section is shown in the following
table.
- 91-