ACD320 user manual
Parameter Description
F3.13
Current fault type
0~29
Record three recent fault types: 0 is no fault; 1~22 is 22 different kinds of fault. For
details,please see fault analysis.
Function Code
Name
Setting Range
Default
Value
F3.14
Operat ing frequency at
current fault
The output frequency
when current fault
happens
0.00Hz
F3.15
Output amperage at
current fault
The output amperage
when current fault
happens
0.0A
F3.16
Bus voltage at current
fault
The bus voltage when
current fault happens
0.0V
Function Code
Name
F3.17
F3.18
Reserved
Reserved
Setting Range
Default
Value
6.5 F4Application Function Parameters
Function Code
Name
Setting Range
Default
Value
F4.00
ACCELTime 2
0.1~3600.0s
10.0s
F4.01
DECEL Time 2
0.1~3600.0s
10.0s
Acceleration/Deceleration time can be chosen to be F0.08, F0.09 or above three time
settings. Their meanings are all the same; please refer to F0.08 and F0.09 related description.
TheAcceleration/Deceleration time 0-1 at inverter operation can be chosen through different
combination of multifunction digital input terminals.
Function Code
Name
Setting Range
Default
Value
F4.02
Frequency of JOG running 0.00 ~ F0.04(maximum 5.00Hz
frequency)
F4.03
The acceleration time of
0.1~3600.0s
10.0s
JOG running
- 82-