ACD320 user manual
Parameter Description
MI6
32
0
For example:If input state displays 3, it means terminal MI1, MI2 is effective, and the other
terminals are ineffective .
Output terminal state display with 10 hexadecimal, as following table:
Output terminal
Effective
Ineffective
TA/B/C
1
0
RA/B/C
2
0
DO
4
0
If output state displays 3, it means that terminalTA/TB/TC、RA/RB/RC are effective, and
DO terminal is ineffective .
The display of operating status of F3.07 selected preferentially.
0:The displaying content in operating state is selected by SHIFT key of the keyboard.
1--15: Correspond to F3.05 displaying contents.
In run status, switch to the displaying content that the parameter selects with 10 seconds
delay when there is no SHIFT key operation.
Automatically switch to the displaying content that the parameter selects when switching
from stop status to run status.
Function Code
Name
Setting Range
Default
Value
F3.08
IGBT module temperature
0~100.0℃
Actual
value
F3.09
Software version
Actual
value
Accumulative operating
F3.10
0~65535h
0
time
These functions only can be viewed but can not be modified.
IGBTmodule temperature: indicates the temperature of the inverter IGBTmodule.
Over-temperature protection value of different invertermay be different.
Software version: software version number.
Inverter accumulative operating time: displays current inverter accumulative operation time.
Function Code
Name
Setting Range
F3.11
F3.12
The fault before previous
fault type
Previous fault type
0~29
0~29
Default
Value
- 81-