ACD320 user manual
Parameter Description
BIT8: PID setpoint
256
8
BIT9: PID feedback
512
9
BIT10: Input terminal status
1024
10
BIT11: Output terminal status
2048
11
BIT12: AVI value
4096
12
BIT13: ACI value
8192
13
BIT14: Current segment of
16384
14
multi-speed control
BIT15:Torque setting value
32768
15
Stop status display:
Displayed Message
Code
BIT0:Setting frequency
1
BIT1:DC bus voltage
2
BIT2:Input terminal status
4
BIT3:Output terminal status
8
BIT4:PID setpoint
16
BIT5:PID feedback
32
BIT6:AVI value
64
BIT7:ACI value
128
BIT8:Current segment of multi-speed control
256
Option: setting parameter=the sum total of display code for example:
require to display at operation status:Output current,Running speed,Output power
4+16+32=52, then setting F3.05to 52 , its corresponding parameter can be viewed at operation
through pressing button "DATA".
This I/O terminal status is displayed in decimal system,S1 (MO1) corresponding to the
lowest digit.
For instance, input status displays 3 is indicting that terminal S1 and S2 are closed and
others are open.
For details, please see F3.17 and F3.18 description.
Input terminal state display with 10 hexadecimal, as following table:
Input terminal
MI1
MI2
MI3
MI4
MI5
Effective
1
2
4
8
16
- 80-
Ineffective
0
0
0
0
0