ACD320 user manual
Parameter Description
Fig. 6-12Relationship between analog input and setting value
AVI input filtering time determines analog input sensitiveness. Increasing this parameter, in
order to prevent malfunction caused by interference to the analog, can strengthen the
anti-interference ability, but reduce the analog input sensitiveness.
Function Code
Name
Setting Range
Default
Value
F2.14
F2.15
F2.16
ACI lower limit
ACI lower limit
corresponding setting
ACI upper limit
0.00V10.00V
-100.0%100.0%
0.00V10.00V
0.30V
0.0%
9.70V
F2.17
F2.18
ACI upper limit
corresponding setting
ACI input filtering time
-100.0%100.0%
0.00s10.00s
100.0%
0.10s
ACI function settings are similar toVI setting method.
ACD320 Series inverter provides 2 paths of analog input port.
ACD320 Series inverter standard unit has twomultifunction digital output terminal, one (or
two) multifunction relay output terminals and one analog output terminal.
Function Code
Name
F2.19
Relay RA/B/C output
selection
F2.20
DO Open circuit
collector output
selection
- 75-
Setting Range
024
024
Default
Value
3