ACD320user manual
Function parameters list
detection delay
Function
Code
Name
Set range
F7.26
PID
range
adjustable 0~50.0
Operation when set
F7.27
frequency is lower 0:Run at lower limit Freq.
than low limit 1:Run at 0Hz.
frequency
0: Select internal sleeping signal
F7.28
Selcet
signal
sleeping 1: Select external sleeping signal
2: Internal and external signal are valid at the same
time.
1: Run circularly.
Simple
PLC 2: Stop after running for one circulation.
F7.29 running mode
3: Run at the selected speed after running for one
circulation.
The 0st step
F7.30
0~999.9
running time.
The 1st step
F7.31
0~999.9
running time.
The 2nd step
F7.32
0~999.9
running time.
The 3rd
F7.33
0~999.9
step running time.
The 4th step
F7.34
0~999.9
running time.
The 5th step
F7.35
0~999.9
running time.
The 6th step
F7.36
0~999.9
running time.
The 7th step
F7.37
0~999.9
running time.
F7.38
Simple
PLC
selection record or 0: Record when power off
not when power 1: No record when power off.
off.
F7.39 Simple
PLC 0:s
running time unit. 1:min
BIT0: Module protection shield
0:Invalid 1: Valid
1
F7.40 Failure shield
BIT1: Soft overcurrent shield.
0:Invalid 1: Valid
2
BIT2: Over-voltage shield.
0:Invalid 1: Valid
4
Default
Value
10.0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
Modifi Serial
cation No
○ 175
○ 176
○ 177
○ 178
○ 179
○ 180
○ 181
○ 182
○ 183
○ 184
○ 185
○ 186
○ 187
○ 188
× 189
- 50-