ACD320user manual
Function parameters list
F5.07
F6.00
F6.01
F6.02
F6.03
F6.04
F6.05
F6.06
F7.00
point set
The frequency
0.00~200.00Hz/s
decrease rate
F6 Communication Parameters
Communication
address
1~247,0 is the broadcast address
0:1200BPS
1:2400BPS
Baud rate setting
2:4800BPS
3:9600BPS
4:19200BPS
5:38400BPS
Data pattern
0: No check N,8,1 for RTU
1: Odd check(E,8,1) for RTU
2: Even check(O,8,1) for RTU
3: No check(N,8,2) for RTU
4: Odd check(E,8,2) for RTU
5: Even check(O,8,2) for RTU
6: No check(N,7,1) for ASCII
7: Odd check(E,7,1) for ASCII
8: Even check(O,7,1) for ASCII
9: No check(N,7,2) for ASCII
10: Oddcheck(E,7,2) for ASCII
11: Even check(O,7,2) for ASCII
12: No check(N,8,1) for ASCII
13: Oddcheck(E,8,1) for ASCII
14: Even check(O,8,1) for ASCII
15: No check(N,8,2) for ASCII
16: Oddcheck(E,8,2) for ASCII
17: Even check(O,8,2) for ASCII
Communication
response delay
0~200ms
Communication
0.0(invalid),0.1~100.0s
overtime fault time
Communication
error measure
0: Alarm and free run stop
1: No alarm and keep running
2: No alarm and stop according to stop mode (by
communication)
Response measure
0: Response whenwrite
1: No response when write
F7 Advanced Function Parameters
Constant pressure 0:One driving two circularly water supply mode is
water supply mode invalid.
50.00
1
3
0
5ms
0.0s
1
0
0
○ 141
○ 142
○ 143
○ 144
○ 145
○ 146
○ 147
○ 148
○ 149