ACD320user manual
F4.22
F4.23
F4.24
F4.25
F4.26
F4.27
F4.28
F4.29
F4.30
F4.31
F4.32
F4.33
F4.34
F4.35
F4.36
F5.00
F5.01
F5.02
F5.03
F5.04
F5.05
Proportional gain
0.00~100.00
(Kp)
Integral time (Ti) 0.01~10.00s
Differential
(Td)
time
0.00~10.00s
Sampling cycletime
0.01~100.00s
(T)
PID
control
0.0~100.0%
discrepancy limit
Feedback
disconnection
0.0~100.0%
detecting value
Feedback
disconnection
0.0~3600.0s
detecting time
Multi-Speed 0
-100.0~100.0%
Multi-Speed 1
-100.0~100.0%
Multi-Speed 2
-100.0~100.0%
Multi-Speed 3
-100.0~100.0%
Multi-Speed 4
-100.0~100.0%
Multi-Speed 5
-100.0~100.0%
Multi-Speed 6
-100.0~100.0%
Multi-Speed 7
-100.0~100.0%
F5 Protection Parameters
0: Noprotection
Motor Overload
1: normal motor
Protection Option
2: Variable Frequency motor
Motor Overload
20%~120.0%(motor rated current)
Protection Current
Power-down
Frequency Drop 70.0~110.0%(standard bus voltage)
Point
Instant power-down
0.00Hz~F0.04
Frequency drop rate
Over-voltage Stall 0: prohibit
Protection
1: allow
Over-voltage Stall 110~150%(380V)
Protection Voltage 110~150%(220V)
F5.06 Over-curent stall 80~200%
- 47-
Function parameters list
1.00
0.10s
0.00s
○ 119
○ 120
○ 121
0.10s
○ 122
0.0%
○ 123
0.0%
○ 124
1.0s
○ 125
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
○ 126
○ 127
○ 128
○ 129
○ 130
○ 131
○ 132
○ 133
1
× 134
100.0% ○ 135
80.0%
○ 136
0.00Hz ○ 137
0
120%
115%
160%
○ 138
○ 139
○ 140