ACD320user manual
Function parameters list
The deceleration
F4.04 time of JOG
0.13600.0s
10.0s
○ 101
running
F4.05 Skip frequency
0.00F0.04
0.00Hz ○ 102
F4.06 Skip frequency
range
0.00F0.04
0.00Hz ○ 103
Traverse frequency
F4.07 range
0.00100.0%relative to set frequency
0.00%
○ 104
Kick frequency
F4.08 range
0.00 50.0% relative to traverse frequency
range
0.00%
○ 105
Traverse frequency
F4.09
0.13600.0s
up time
5.0s
○ 106
Traverse frequency
F4.10
0.13600.0s
down time
5.0s
○ 107
F4.11
Fault
times
auto-reset 03
0
○ 108
Interval time setting
F4.12 of
automatic 0.1100.0s
1.0s
○ 109
resetting fault
FDT level detection
F4.13
0.00F0.04
value
5.00Hz ○ 110
FDT
delay
F4.14
0.00100.0%FDT level)
detection value
5.0%
○ 111
Frequency reaching
F4.15
0.0100.0%maximum frequency
detection range
0.0%
○ 112
Energy
115.0140.0%standard DC bus voltage380V 130.0%
F4.16 consumption(brake)
○ 113
braking voltage
115.0140.0%standard DC bus voltage220V 120.0%
F4.17 Speed display ratio 0.1999.9%
100.0% ○ 114
Speed=120×runningfrequency×F4.17/pole number
0: Given by Keyboard(F4.19)
F4.18 PID setpoint
Sources Option
1: Given by Analog Channel AVI
2: Given by Analog Channel ACI
3: Given by Remote Communication
0
× 115
4: Multi-speed setpoint
F4.19 Preset PID setpoint 0.0%100.0%
0.0%
○ 116
0: AVI Feedback
F4.20
1: ACI Feedback
PID
Feedback
2: AVI+ACI Feedback
Sources Option
3: Communication feedback
0
× 117
4: AVI-ACI Feedback
F4.21
PID Output
Characteristics
Option
0: Positive
1: Negative
0
× 118
- 46-
    "