ACD320user manual
Function parameters list
of M key
1.Switch between running forward and reverse
2: Elimate the set of UP/DOWN
F3.03
F3.04
F3.05
0:Keypad control valid
STOP function opt 1: Keypad and terminal control valid
ion
2: Keypad and communication control valid
3: All control modes valid
Reserved
Displayed Message
Code
BIT0: Running frequency
1
BIT1: Setting frequency
2
BIT2: Output current
4
BIT3: Output voltage
8
BIT4: Running speed
16
BIT5: Output power
32
operation
display
option
status
parameter
BIT6: Output torque
BIT7: DC bus voltage
BIT8: PID setpoint
BIT9: PID feedback
64
128
256
512
BIT10: Input terminal status
1024
BIT11: Output terminal status
2048
BIT12: AVI value
4096
BIT13: ACI value
8192
BIT14: Current segment of
multi-speed control
16384
BIT15: torque setting value
32768
0
81
2
82
1183
83
Note: The set value is the sum of all displayed code, if the inverter need to display output current, running speed,
bus-bar voltage, set the value 4+16+128=148, the parameter can be displayed after saving and exiting the
set period.
BIT0Setting frequency
1
BIT1DC bus voltage
2
BIT2Input terminal status
4
BIT3Output terminal status
8
Stop status display BIT4PID setpoint
16
F3.06
parameter option BIT5PID feedback
32
207
84
BIT6AVI value
64
BIT7ACI value
128
BIT8Current segment of
256
multi-speed control
operation status
F3.07 display preferential 015(0:invalid)
0
85
option
IGBTmodule
F3.08
temperature
0100
Actual
*
86
value
F3.09 Software version 0.00655.35
Actual
value
*
87
Accumulative
F3.10
operat ing time
065535h
0
*
88