ACD320user manual
Function parameters list
5: Motor running reverse
6: Null speed operating
7: Upper limit frequency reached
8: Lower limit frequency reached
912: Reserved
13:High pressure arrives detect value
14:Low pressure arrives detect value
15:Sleep status indication
Relay
TA/B/C 16:Lack of water alarm ingdication.
F2.21 output selection
17:Non-zero speed operating.
3
18:Running
19:Reserved
20:Reserved
21:Simple PLC run for a cycle until output of
signal.
22:Reserved
23:Reserved
24:Reserved
72
0: Setting frequency
1: Running frequency
2: Output current
3:Output voltage
F2.22
AO1 Analog output 4: Running speed
Selection
5: Outputpower
0
73
6: Output torque
7: AVI input value
8: ACI input value
910: Reserved
F2.23 AO1 Lower limit 0.0%100.0%
0.0%
74
Lower limit
F2.24 corresponding AO1 0.00V100.0V
output
0.00V
75
F2.25 AO1 Upper limit 0.0%100.0%
100.0% ○
76
Upper limit
F2.26 corresponding
0.00V100.0V
10.00V ○
77
AO1 output
F3 HumanMachine Interface Parameters
F3.00 User password
065535
0
78
0: General-purpose inverter
1233: The application macro of Offset printing
F3.01
Application
of machine
macroinstruction 1235: The application macro of engraving
0
machine
×
79
1237:Constant pressure water supply
macroinstruction
F3.02 Function selection 0Jog running
0
80
- 43-
    "