ACD320user manual
Function parameters list
Conservation
1: Energy Conservation
Selection
F2 Input and Output Terminal Function Parameters
F2.00
On-off signal filter
times
1~10
5
MI1 Terminal
0: No Function
F2.01
0
Function Selection 1: Forward
MI3 Terminal
2: Reverse
F2.02 Function Selection 3: three-wire control
0
MI3 Terminal
4: Forward Jogging
F2.03 Function Selection 5: Reverse Jogging
0
F2.04
MI4/FWD Terminal 6: Free run stop
Function Selection 7: Failure reset
1
MI5/REV Terminal 8: External fault input
F2.05 Function Selection 9: Frequency setting(UP)
2
10: Frequency setting(DOWN)
11: Frequency up/down setting clear
12: Multi-Speed Terminal 1
13: Multi-Speed Terminal 2
14: Multi-Speed Terminal 3
15: ACCEL/DECELTime selection
16: PID control pause
17: Traverse pause at current frequency
18: Traverse reset
19: ACCEL/DECEL forbid
20: external sleep signal
Function selection 21: Reserved
F2.06
of terminal MI6
22: Reserved
0
23 : One driving two water supply mode is
ineffective(switch to manual operation)
24: Reserved
25:Simple PLC run reset
26:Simple PLC run ineffective
27:Switch to set of ACI frequency
28:Jog key
29:Torque control forbidden
30:Eliminate the increasing or decreasing set of
frequency temporarily.
31:Reserved.
○
51
×
52
×
53
×
54
×
55
×
56
×
57
F2.07
F2.08
Terminal
mode
0: two-wirecontrol 1
control 1: two-wirecontrol 2
2: three-wire control 1
3: three-wire control 2
UP/DOWN
0.01~50.00Hz/s
0
×
58
0.50Hz/s ○
59