ACD320user manual
Function parameters list
F1.05 Motor rated current 0.1~1000.0A
Set by
×
31
model
Motor stator
F1.06
resistance
0.001~65.535Ω
Set by
○
32
model
Motor rotor
F1.07
resistance
0.001~65.535Ω
Set by
○
33
model
Motor stator/rotor
F1.08
0.1~6553.5mH
inductance
Set by
○
34
model
F1.09
Mutual inductance
of motor
stator/rotor
0.1~6553.5mH
Set by
model
○
35
F1.10 No-load current 0.01~655.35A
Set by
○
36
model
F1.11
Self-learning
of 0: NO operation
1: complete tuning Self-learnin
motor parameters
2: static tuning Self-learning
0
×
37
F1.12 Speed loop
0~100
proportional gain1
30
○
38
Speed loop integral
F1.13 time1
0.01~10.00s
0.50s
○
39
Switching low
F1.14
point frequency
0.00Hz~F1.17
5.00Hz ○
40
Speed loop
F1.15
0~100
proportional gain 2
10
○
41
Speed loop integral
F1.16
0.01~10.00s
time 2
1.00s
○
42
F1.17
Speed loop integral
time 2
F1.14~F0.04
10.00Hz ○
43
VC slip
F1.18 compensating
50%~200%
100%
○
44
factor
Upper torque limit
F1.19
0.0~200.0% (inverter rated current)
setting
150.0% ○
45
0: Linear V/F curve
F1.20 V/F curve setting
1: square torque V/F curve
0
×
46
F1.21 Torque boost
0.0%(auto) 0.1%~30.0%
0.0%
○
47
F1.22
Torque boost
cut-off
0.0~80.0% (relative to motor rated frequency)
60.0%
×
48
V/F slip
F1.23
0.0~200.0%
compensation limit
0
○
49
F1.24 Energy
0: No Operation
0
○
50
- 40-