ACD320user manual
Function parameters list
Chapter 5 Function parameters list
5.1 Symbol description
× ---- parameter can’t be changed in process of running
○ ---- parameter can be changed in process of running
* ---- read-only parameter, unmodifiable
5.2 Function parameter schedule graph
Function
Code
Name
Set range
Default Modifi Serial
Value cation No
H0—Basic run function parameter group
0: Speed sensorless vector control (SVC)
F0.00 Control mode
1: V/F control
1
×
0
2:open loop torque control
F0.01
Command
selection
0: Keyboard
source
1: Terminal
2: Communication
0
×
1
0: Valid, and inverter memorize when power down
Keyboard and
1: Valid, and inverter does not memorize when
F0.02 terminal
0
power down
UP/DOWN setting 2: Invalid
2
0: Keyboard
1: AVI
2: ACI
Frequency
3: AVI+ACI
F0.03 command
4: Multi-speed
0
3
Selection
5: PID control
6: 485communication
7: simple PLC
8: keypad analog potentiometer
F0.04 Maximum output 10.00600.00Hz
frequency
50.00Hz ×
4
Upper limit
F0.05 frequency
F0.06F0.04
50.00Hz ○
5
Lower limit
F0.06
frequency
0.00HzF0.05
0.00Hz ○
6
Keyboard
F0.07
frequency setting
0.00HzF0.04
50.00Hz ○
7
F0.08 ACCEL time 1
0.13600.0s
10.0s
8
F0.09 DECEL time 1
0.13600.0s
10.0s
9
F0.10
0: Operating at default direction
Operation direct ion
1: Operating at reverse direction
selection
2: NO inverse operating
0
×
10
- 38-
    "