ACD320user manual
Installation and wiring
3.2.2 周边设备配线图及其应用注意事项:
Wiring Diagram of Peripheral Equipment and the notice
①Power supply:voltage levels:220V,400V。
Input power supply ① ②fuse or the Electric leakage chopper
Fuse or leaking current breaker
Please use fuse that conform to the rated voltage
and current level of inverter.
②
Be used to control the power of inverter, it palys
a role of protecting the inverter. Used to switch run and
③
stop is forbidden.
④
③Magnetic control conductor
⑤
Do not use magnetic control conductor for power switch
of the inverter, for which may reduce the inverter life.
⑥
④Input end AC reacter:
It can effectively restrain the harmonics of power supply wire,
R
S
T
P2
320
P1
Series B2
or improve the power factor when the imbalance of main power supply
⑦ voltage is more than 3%(and the power capacity is larger than 500KVA
at the same time) or when power supply voltage changes dramatically.
inverter
DC-
⑧
⑤Radio interference filter
Nearby equipment, such as radio receiver, may brings electromagnetic
U
V
W
disturbance noise. The EMC radio interference filter is helpful for reducing
radio noise.
⑨
⑥EMI filter
⑩
Reduce the noise conducting by the power supply wire produced by
M
Motor
~
inverter.
⑦DC reactor
To inhibit high-order harmonics produced by inverter.
⑧Braking Resistors and braking Units
Improve braking Torque of inverter, or be used in occasions that ON/OFF
Fig.3-2 Wiring of
Peripheral Equipment
is operated frequently and rotatory inertia is great.
⑨Output end noise filter
Reduce the noise from output of inverter.
⑩Input end AC reacter:
Reduce the motor vibration caused by power supply switch waveform.
When wire between inverter and motor is long than 10 meters, which
can also restrain th-e1h9a-rmonics.