ACD320 user manual
Appendix
F7.21
F7.22
F7.23
F7.24
F7.25
F7.28
Sleep detection
frequency
Sleep detection
delay
Revival pressure
Revival detection
delay
Water-lack detection
delay
Selection of
sleeping signal
0Maximum frequency
0999.9s
1100
0999.9s
0999.9s
02
0
170
0
171
0
172
0
173
0
174
0
177
2. Detailed description of the parameters
Function code
F0.08
F0.09
Name
Acce. Time 1
Dece. Time 1
Setting range
0.13600.0s
0.13600.0s
Factory value
10.0s
10.0s
The acceleration and deceleration time at PID contol is set according to the actual situation.
Function code
Name
Setting range
Factory
value
Operation status display
F3.05
parameter option
165535
1183
Stop status display
F3.06
1511
207
parameter option
Operation status display 0150: It is invalid to
F3.07
0
preferential option.
select preferentially
F3.05=775 is set at PID control, (display the running frequency, setting frequency, output
current , PID provision, PID feedback value), F3.06=51 (display setting frequency, bus-bar
voltage, PID value, PID feedback value), F3.07=8 (display PID value preferential), the user can
set accordingly. The detailed explanation of parameters is refered in Chapter 6.
Function code
Name
Setting range
Factory
value
F9.02
F9.03
Acce. Time 3
Dece. Time 3
0.13600.0s
0.13600.0s
445.0s
445.0s
The set of accelerating and decelerating time at PID control, this parameter is related to the
set of F4.26 and F7.26, as shown in the following instructions.
- 145-
    "