ACD320 user manual
BIT6:RA,RB,RC
64
BIT7:DO-R
128
BIT8:TA,TB,TC
256
Parameter Description
Function Code
Name
Setting Range
Default
Value
Carrier wave selection
F9.01
with the temperature
0:Invalid
1
1: Valid
adjustment
When it is effective that carrier wave adjusts with the temperature, inverter detect the
temperature of IGBT heat sink, the carrier wave frequency will change automatically when
exceeding a certain value. Set it invalid for the noise scene of high requirements.
Function Code
Name
Setting Range
Default
Value
F9.02
Accelerating time 3
0.1~3600.0
20.0
F9.03
Decelerating time 3
0.1~3600.0
20.0
Only when the constant pressure water supply PID is valid, the absolute value of
inaccuracy between feedback pressure and the set pressure, within PID adjustment range (F7.26),
F9.02 and F9.03 is valid.
Function Code
Name
Setting Range
Default
Value
AO2 analog output
F9.09
0~10
0
selection
Standard output of analog output is 0 ~ 20mA or 0 ~ 10V, current or voltage output can be
selected by controlling the J5. The range of the corresponding value it indicates is as shown in
the following table:
Setting
0
1
2
Function
Set frequency
Running frequency
Output current
Range
0 to maximum
output frequency
0 to maximum
output frequency
0 to 200% of the rated current of the
- 107-