ACD320 user manual
Parameter Description
BIT3: Reserved
8
BIT4: Inverter overload shield.
16
0:Invalid 1: Valid
BIT5: Input lack-phase shield.
32
0:Invalid 1: Valid
BIT6: Output lack-phase shield.
64
0:Invalid 1: Valid
BIT7: Reserved
128
BIT8: Current detecting circuit failure
256
0:Invalid 1: Valid
BIT9: Earthing short circuit failure
shield.
512
0:Invalid 1: Valid
BIT10: Inverter over heating shield.
0:Invalid 1: Valid(all frequency
1024
section is valid)
If soft overcurrent shield inverter overload shield are needed, set F7.40=2+64=66.
Please refer to F8.09 for detailed description of hardware overcurrent shield.
6.9 F8 Supplementary function Parameters 1
Function Code Name
Setting Range
Default
Value
Inhibit oscillation low
F8.00
0500
5
frequency threshold point
Inhibit oscillation high
F8.01
0500
100
frequency threshold point
Current oscillation is prone to occur when the motor is running at certain frequency
segments, the light is to cause the motor instable running, and the serious is to cause inverter
overcurrent. When F8.04=0, enable vibration suppression functionwhen the set of F8.00, F8.01
is small, oscillation restraining effect and current increasing is obvious, and when the set of
F8.00, F8.01 is large, oscillation restraining effect is weak.
Function Code
Name
Setting Range
Default
Value
F8.02
Inhibit oscillation scope
limit value
010000
5000
- 103-
    "