Chapter 5 Parameters|VFD-B Series
Parameter Explanation
Settings
07-12
07-13
07-14
07-15
Torque
Compensation Time
Constant
Slip Compensation
Time Constant
Accumulative Motor
Operation Time
(Min.)
Accumulative Motor
Operation Time
(Day)
0.01 ~10.00 Sec
0.05 ~10.00 sec
00 to 1439 Min.
00 to 65535 Day
Factory
Setting
Customer
0.05
0.10
00
00
Group 8 Special Parameters
Parameter Explanation
Settings
08-00
08-01
08-02
08-03
08-04
08-05
08-06
08-07
08-08
08-09
08-10
08-11
08-12
08-13
DC Brake Current
Level
00 to 100%
DC Brake Time
during Start-Up
0.0 to 60.0 sec
DC Brake Time
during Stopping
0.0 to 60.0 sec
Start-Point for DC
Brake
0.00 to 400.00Hz
00: Operation stops after momentary power
loss
Momentary Power
Loss Operation
Selection
01: Operation continues after momentary
power loss, speed search starts with the
Master Frequency reference value
02: Operation continues after momentary
power loss, speed search starts with the
minimum frequency
Maximum Allowable
Power Loss Time
0.1 to 5.0 sec
B.B. Time for Speed
Search
0.1 to 5.0 sec
Current Limit for
Speed Search
30 to 200%
Skip Frequency 1
Upper Limit
0.00 to 400.00 Hz
Skip Frequency 1
Lower Limit
0.00 to 400.00 Hz
Skip Frequency 2
Upper Limit
0.00 to 400.00 Hz
Skip Frequency 2
Lower Limit
0.00 to 400.00 Hz
Skip Frequency 3
Upper Limit
0.00 to 400.00 Hz
Skip Frequency 3
Lower Limit
0.00 to 400.00 Hz
Factory
Setting
Customer
00
0.0
0.0
0.00
00
2.0
0.5
150
0.00
0.00
0.00
0.00
0.00
0.00
5-14
Revision July 2008, BE16, SW V4.08 & V5.00