Chapter 5 Parameters|VFD-B Series
Group 5 Multi-Step Speed and PLC Parameters
Parameter Explanation
Settings
05-00
05-01
05-02
05-03
05-04
05-05
05-06
05-07
05-08
05-09
05-10
05-11
05-12
05-13
05-14
1st Step Speed
Frequency
2nd Step Speed
Frequency
3rd Step Speed
Frequency
4th Step Speed
Frequency
5th Step Speed
Frequency
6th Step Speed
Frequency
7th Step Speed
Frequency
8th Step Speed
Frequency
9th Step Speed
Frequency
10th Step Speed
Frequency
11th Step Speed
Frequency
12th Step Speed
Frequency
13th Step Speed
Frequency
14th Step Speed
Frequency
15th Step Speed
Frequency
0.00 to 400.00 Hz
0.00 to 400.00 Hz
0.00 to 400.00 Hz
0.00 to 400.00 Hz
0.00 to 400.00 Hz
0.00 to 400.00 Hz
0.00 to 400.00 Hz
0.00 to 400.00 Hz
0.00 to 400.00 Hz
0.00 to 400.00 Hz
0.00 to 400.00 Hz
0.00 to 400.00 Hz
0.00 to 400.00 Hz
0.00 to 400.00 Hz
0.00 to 400.00 Hz
00: Disable PLC operation
01: Execute one program cycle
05-15
05-16
05-17
05-18
05-19
05-20
05-21
PLC Mode
02: Continuously execute program cycles
03: Execute one program cycle step by step
04: Continuously execute program cycles
step by step
PLC Forward/
Reverse Motion
00 to 32767 (00: FWD, 01: REV)
Time Duration of 1st 00 to 65500 sec or 00 to 6550.0 sec
Step Speed
Time Duration of 2nd 00 to 65500 sec or 00 to 6550.0 sec
Step Speed
Time Duration of 3rd 00 to 65500 sec or 00 to 6550.0 sec
Step Speed
Time Duration of 4th 00 to 65500 sec or 00 to 6550.0 sec
Step Speed
Time Duration of 5th 00 to 65500 sec or 00 to 6550.0 sec
Step Speed
Factory
Setting
Customer
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
00
00
00
00
00
00
00
5-10
Revision July 2008, BE16, SW V4.08 & V5.00