Parameter Explanation
00-10 Reserved
Settings
Chapter 5 Parameters|VFD-B Series
Factory
Setting
Customer
Group 1 Basic Parameters
Parameter Explanation
01-00
01-01
Maximum Output
Frequency (Fmax)
Maximum Voltage
Frequency (Fbase)
Settings
50.00 to 400.00 Hz
0.10 to 400.00 Hz
Factory
Setting
Customer
60.00
60.00
01-02
01-03
01-04
01-05
Maximum Output
Voltage (Vmax)
Mid-Point Frequency
(Fmid)
Mid-Point Voltage
(Vmid)
Minimum Output
Frequency (Fmin)
230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
575V series: 0.1V to 637.0V
0.10 to 400.00 Hz
230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
575V series: 0.1V to 637.0V
0.10 to 400.00 Hz
220.0
440.0
575.0
0.50
1.7
3.4
4.8
0.50
01-06
Minimum Output
Voltage (Vmin)
230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
1.7
3.4
575V series: 0.1V to 637.0V
4.8
01-07
Output Frequency
Upper Limit
1 to 120%
100
01-08
Output Frequency
Lower Limit
0 to100 %
0
01-09 Accel Time 1
0.01 to 3600.0 sec
10.0
01-10 Decel Time 1
0.01 to 3600.0 sec
10.0
01-11 Accel Time 2
0.01 to 3600.0 sec
10.0
01-12 Decel Time 2
0.01 to 3600.0 sec
10.0
01-09 ~ 01-12: Factory setting for models of 30hp (22kW) and above is 60sec.
01-13 Jog Acceleration
Time
0.1 to 3600.0 sec
1.0
01-14 Jog Frequency
0.10 Hz to 400.00 Hz
6.00
00: Linear Accel/Decel
Auto acceleration / 01: Auto Accel, Linear Decel
01-15
deceleration (refer to 02: Linear Accel, Auto Decel
Accel/Decel time
03: Auto Accel/Decel (Set by load)
00
setting)
04: Auto Accel/Decel (set by Accel/Decel
Time setting)
01-16
Acceleration S-
Curve
00 to 07
00
01-17
Deceleration S-
Curve
00 to 07
00
01-18 Accel Time 3
0.01 to 3600.0 sec
10.0
01-19 Decel Time 3
0.01 to 3600.0 sec
10.0
01-20 Accel Time 4
0.01 to 3600.0 sec
10.0
Revision July 2008, BE16, SW V4.08 & V5.00
5-3