Chapter 3 Start Up|VFD-B Series
3.2 Operation Method
Refer to 4.2 How to operate the digital keypad VFD-PU01 and chapter 5 parameters for setting.
Please choose a suitable method depending on application and operation rule. The operation is
usually used as shown in the following table.
Operation Method
PU01 keypad
Operate from
external signal
Frequency Source
Operation
Command Source
RUN
STOP
RESET
MI1
MI2
DCM
AVI, ACI, AUI
Parameter
setting:
04-04=11
04-05=12
External terminals
input:
FWD-DCM
REV-DCM
3.3 Trial Run
After finishing checking the items in “3.1 preparation before start-up”, you can perform a trial run.
The factory setting of the operation source is from the keypad (Pr.02-01=00).
1. After applying power, verify that LED “F” is on and the display shows 60.00Hz.
2. Setting frequency to about 5Hz by using
key.
3. Pressing RUN key for forward running. And if you want to change to reverse running,
you should press
F
H
key in U
page. And if you want to decelerate to stop,
STOP
please press RESET key.
4. Check following items:
„ Check if the motor direction of rotation is correct.
„ Check if the motor runs steadily without abnormal noise and vibration.
„ Check if acceleration and deceleration are smooth.
If the results of trial run are normal, please start the formal run.
3-2