Chapter 2 Installation and Wiring|VFD-B Series
WARNING!
1. Short-circuiting [B2] or [-] to [+2/B1] can damage the AC motor drive.
Grounding terminals ( )
Make sure that the leads are connected correctly and the AC drive is properly grounded.
(Ground resistance should not exceed 0.1Ω.)
Use ground leads that comply with local regulations and keep them as short as possible.
Multiple VFD-B units can be installed in one location. All the units should be grounded
directly to a common ground terminal, as shown in the figure below. Ensure there are no
ground loops.
excellent
good
2.4.4 Control Terminals
Circuit diagram for digital inputs (SINK current 16mA.)
not allowed
SINK Mode
+24
multi-input
te rm in al
SOURCE Mode
Multi-Input
Terminal
DCM
Internal Circuit
DCM
Terminal symbols and functions
Terminal
Symbol
Terminal Function
FWD Forward-Stop command
REV Reverse-Stop command
+24V
Internal Circuit
ON:
OFF:
ON:
OFF:
Factory Settings (SINK)
ON: Connect to DCM
Run in FWD direction
Stop acc. to Stop Method
Run in REV direction
Stop acc. to Stop Method
Revision July 2008, BE16, SW V4.08 & V5.00
2-21