Appendix B Accessories|VFD-B Series
B.6 AC Reactor
B.6.1 AC Input Reactor Recommended Value
230V, 50/60Hz, 1-Phase
kW
HP
Fundamental
Amps
Max. continuous
Amps
Inductance (mH)
3~5% impedance
0.75
1
8
12
1.5
1.5
2
12
18
1.25
2.2
3
18
27
0.8
460V, 50/60Hz, 3-Phase
kW
HP
Fundamental
Amps
Max.
continuous
Amps
Inductance (mH)
3% impedance 5% impedance
0.75
1
4
6
9
12
1.5
2
4
6
6.5
9
2.2
3
8
12
5
7.5
3.7
5
8
12
3
5
5.5 7.5
12
18
2.5
4.2
7.5
10
18
27
1.5
2.5
11
15
25
37.5
1.2
2
15
20
35
52.5
0.8
1.2
18.5 25
35
52.5
0.8
1.2
22
30
45
67.5
0.7
1.2
30
40
55
82.5
0.5
0.85
37
50
80
120
0.4
0.7
45
60
80
120
0.4
0.7
55
75
100
150
0.3
0.45
75
100
130
195
0.2
0.3
B-32