Chapter 7 Troubleshooting |VFD-B Series
7.9 Motor cannot Run
Motor cannot run
Check PU01
for normal
No
display
Yes
Reset after clearing Yes Check if there is any
fault and then RUN
fault code displayed
No
Check if non-fuse
breaker and magnetic
No
Set them to ON
contactor are ON
Yes
Check if input
No
voltage is normal
Yes
Check if any faults
occur, such as
Lv, PHL or
disconnection
It can run when
no faults occur
Input "RUN"
command
by keypad
No
If jumper or DC
No
reactor is connected
between +1 and +2/B1
Use jumper
or DC reactor
Press RUN key to
check if it can run
Yes
Yes
Maybe AC motor drive has malfunction or misoperation
due to noise. Please contact DELTA.
Press UP key to
set frequency
Yes
Press UP to
check if motor
can run
No
No Check if input FWD
No
Check if the wiring
of terminal FWD
or REV command
and between
REV-DCM is correct
Yes
No Set frequency or not No
No
Correct connection
Yes
Change switch or relay
Modify frequency
Yes
setting
No
if upper bound freq.
and setting freq. is
Check if the parameter
lower than the min.
output freq.
setting and wiring of
analog signal and
Yes Change defective
potentiometer and
No
multi-step speed
are correct
relay
Motor has malfunction
No
Check if there is any
output voltage from
No
Maybe AC motor drive has malfunction.
terminals U, V and W
Please contact DELTA.
If load is too large
Yes
Yes
Yes
Check if the setting
of torque
Yes
Check if motor
connection
is correct
No
Connect correctly
compensation
is correct
Motor is locked due to large load, please reduce load.
No
For example, if there is a brake, check if it is released.
Increase the setting of
torque compensation
7-6
Revision July 2008, BE16, SW V4.08 & V5.00