Chapter 7 Troubleshooting
7.1 Over Current (OC)
ocA
Ov er-cur re nt
dur ing ac c eleratio n
o cd
Over- c ur rent
dur ing decele ration
OC
Ove r curren t
Remove short c ircuit Yes
or groun d fault
Reduce the load or
Ye s
increase the power
of AC motor drive
Check if there is any short c irc uits and
groun ding between t he U, V, W and motor
No
No
No
Check if load is too large
No
No
No
N o Reduce tor que
compen sation
Yes
No Suitable tor que
c o m pe n s a ti o n
Ye s
Red uce tor que
com pensa tion
Check if
Check if
No acceler ation time No dec eleration time
is too short by
is too short by
load inertia.
loa d inertia.
Ye s
Maybe AC motor dri ve
has malfunction or error
due to noise. Pleas e
contact DELTA.
Ye s
No Has l oad cha nged
s u d de n l y ?
Ye s
Ye s
Inc re ase ac cel/dec el
ti m e
Can ac celerati on
Yes Can dec elerati on
time be made longer?
time be made l onger?
No
No
R educe load or increase
t he pow er of AC motor
driv e
Reduce lo ad or in crease
t he pow er of AC motor
dri ve
Check br ake
me thod. P lease
co ntact D ELTA
Revision July 2008, BE16, SW V4.08 & V5.00
7-1