Chapter 5 Parameters|VFD-B Series
Group 5: Multi-step speeds and PLC (Process Logic Control) parameters
05 - 00
05 - 01
05 - 02
05 - 03
05 - 04
05 - 05
05 - 06
05 - 07
05 - 08
05 - 09
05 - 10
05 - 11
05 - 12
05 - 13
05 - 14
1st Step Speed Frequency
2nd Step Speed Frequency
3rd Step Speed Frequency
4th Step Speed Frequency
5th Step Speed Frequency
6th Step Speed Frequency
7th Step Speed Frequency
8th Step Speed Frequency
9th Step Speed Frequency
10th Step Speed Frequency
11th Step Speed Frequency
12th Step Speed Frequency
13th Step Speed Frequency
14th Step Speed Frequency
15th Step Speed Frequency
Settings
0.00 to 400.00 Hz
Unit: 0.01
Unit: 0.01
Unit: 0.01
Unit: 0.01
Unit: 0.01
Unit: 0.01
Unit: 0.01
Unit: 0.01
Unit: 0.01
Unit: 0.01
Unit: 0.01
Unit: 0.01
Unit: 0.01
Unit: 0.01
Unit: 0.01
Factory Setting: 0.00
The Multi-Function Input Terminals (refer to Pr.04-04 to 04-09) are used to select one of the
AC motor drive Multi-step speeds. The speeds (frequencies) are determined by Pr.05-00 to
05-14 as shown above. They are also used in conjunction with Pr.05-15 to 05-31 for PLC
programs.
05 - 15 PLC Mode
Settings
00
01
02
03
04
Factory Setting: 00
Disable PLC operation
Execute one program cycle
Continuously execute program cycles
Execute one program cycle step by step
Continuously execute program cycles step by step
This parameter selects the mode of PLC operation for the AC motor drive. The AC motor drive
will change speeds and directions according to the desired user programming.
This parameter can be applied in the PLC operation of general small machines, food
processing machines and washing equipment.
Revision July 2008, BE16, SW V4.08 & V5.00
5-59